RE: Personnel Contamination Monitoring
At Prairie Island, we use a National Nuclear Corp. (NNC) Gamma-60 portal and
NNC Friskalls. Both checks are required upon exit from the RCA. The
Gamma-60 portal is set at about 150 nCi and the Friskalls (3) at about 4
nCi. We have another Gamma-60 at the guardhouse exit which is set at about
190 nCi. For suspected radon daughter contamination we look at half life,
beta/gamma to alpha ratio (using portable instrument) or gamma spec. Let me
know if you need more information.
Travis N. Beard, Corp. H.P.
> -----Original Message-----
> From: IRA M. TURNER [SMTP:TURNEIM@GWSMTP.NU.COM]
> Sent: Tuesday, December 28, 1999 11:06 AM
> To: Multiple recipients of list
> Subject: Personnel Contamination Monitoring
>
> Millstone is currently examining existing practices regarding monitoring
> of
> personnel at the exit from the RCA. This look at current practices is to
> evaluate use of various instruments including the PCM, CM-11, friskers,
> etc,...
> Included is an evaluation of methods for alpha and radon monitoring.
>
> I would appreciate it if other program owners could forward copies of
> procedures for this type of monitoring.
> Unfortunately, I need these for perspective in order to settle a "debate,"
> and
> therefore, the sooner the better.
> I thank you in advance for your assistance.
>
> Ira M. Turner
> Supervisor Health Physics Support
> Millstone Nuclear Power Station
>
> 860-447-1791 x 4433
> turneim@nu.com
> ************************************************************************
> The RADSAFE Frequently Asked Questions list, archives and subscription
> information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html