[ RadSafe ] Dose rate limits
Stabin, Michael
michael.g.stabin at Vanderbilt.Edu
Wed Mar 29 08:27:27 CST 2006
>for restricted areas such as the x-ray control booth you discuss,
there are no dose rate limits in any jurisdiction that I know
I have heard that in the USA, two states, MI and PA, have imposed
additional protection limits (above the standard US-wide annual dose
limits) based on instantaneous dose rates, that are used in shielding
calculations:
MI: 13.9 nSv/s controlled or uncontrolled
PA: 5.6 nSv/s for uncontrolled
Am I correct about that? Thanks.
Mike