Actually, you should refer to the Increased Control Requirements at:
_http://www.nrc.gov/security/byproduct/orders.html#increasedcontrols_
(http://www.nrc.gov/security/byproduct/orders.html#increasedcontrols)
Specifically, a footnote to Table 1: Radionuclides of Concern states:
"Radioactive materials are to be considered aggregated or collocated if
breaching a common physical security barrier (e.g., a locked door at the entrance
to a storage room) would allow access to the radioactive material or devices
containing the radioactive material."
Additional guidance on aggregation is provided in the "Implementing Guidance
and Questions and Answers" and "Supplemental Questions and Answers" at the
same site.
Barbara L. Hamrick
In a message dated 8/4/2007 9:02:02 AM Pacific Daylight Time,
GRMarshall at philotechnics.com writes:
Syd,
If the sources are inside the same security area (i.e.- if a person
would have access to both sources after passing through a single
security checkpoint), then yes, you would fall under increased controls.
It doesn't matter if they are in different buildings or a half-mile
apart. And it doesn't matter if the sources are bolted down or attached
to a pipe. So, yes, the inspector was correct.
Glenn Marshall, CHP
-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl] On
Behalf Of Syd H. Levine
Sent: Saturday, August 04, 2007 12:41 AM
To: Robert D Gallagher; Jean-Francois, Stephane; radsafe at radlab.nl
Subject: Re: [ RadSafe ] Security and background check
forradioactivematerialusers
Bob, or others who know about such things:
NRC also has orders in place to enhance security if a facility has over
the
quantity of concern, around 16 Ci in the case of AmBe sources, I
believe.
We have had an inspector here in Kentucky insist that NRC includes
cumulative activity in that determination. This particular regulated
entity
has a 15 and a 3 Ci AmBe source and is being told to get ready to do the
increased security dance. Is this correct?
The fellow jokingly suggested he would put the two sources in two
different
buildings. If the requirement does apply to cumulative activity, what
effect would doing that actually have?
Thanks.