Harry Reynolds
hreynolds at energysolutions.com
Fri Jul 30 08:59:09 CDT 2010
Another potential problem with lapel samplers on the worker is the likelihood of contaminating the filter with loose surface contamination rather than airborne contamination especially in close quarters. This can result in some really scary numbers but bioassay can show that it was not valid.
Harry Reynolds
ASRSO
ENERGYSOLUTIONS
801-649-2219 Desk
801-349-9036 Cell
-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu [mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of grahnk at comcast.net
Sent: Friday, July 30, 2010 5:26 AM
To: radsafe at health.phys.iit.edu
Subject: Re: [ RadSafe ] lapel monitors for potential airborne alpha particulates
Over the years, we've seen a significant difference in levels when comparing work area monitors to lapel sampling. Even with agressive dust control measures, workers handling tarps for daily cover of contaminated soils had the highest exposures. The differences were 500 to 1500 times the area monitors on occasion. Then again, training is an issue. Equipment operators and truck drivers tend to set them on the floor of their cab and vaccuum the floor mats and we got the occasional abnormally high value.
Kelly Grahn
Illinois Emergency Management, Nuclear Safety
----- Original Message -----
From: "JOHN RICH" <JOHN.RICH at sargentlundy.com>
To: radsafe at health.phys.iit.edu
Sent: Thursday, July 29, 2010 9:38:21 PM
Subject: [ RadSafe ] lapel monitors for potential airborne alpha particulates
Radsafers
It has been suggested that D&D workers use lapel monitors for potential airborne alpha particulates IN ADDITION TO a continuous air sampler in the immediate vicinity of the D&D work.
My first thought is that the nuisance factor for the workers is going to be "anti-ALARA."
Can anybody provide some experience with the necessity, effectiveness, and "value added" by lapel monitors vs an air sampler in the immediate vicinity?
Thanx in advance - -jmr
John Rich
312-269-3768
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu _______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu
More information about the RadSafe
mailing list