Syd,

RQ is applicable to Am-241 10 mCi or greater.  RQ on the shipping paper (declaration) must be before the UN number.  (The alternative which is not preferred is after the Class 7 or packing group if applicable.)  RQ is independent of special form or normal form.

Roy A. Parker, Ph.D.
Radiation Physics Consultant 
roy at royparker.org

-----Original Message-----
From: Syd H. Levine <syd.levine at mindspring.com>
Sent: Thursday, March 25, 2010 11:59 PM
To: radsafe at health.phys.iit.edu
Subject: [ RadSafe ] RQ

I am a bit confused by the RQ requirement on packages.  Am I reading the 
regs right that anything containing  over 10 mCi of Am-241 needs the RQ 
after the UN3332 marking?  Does this apply to special form sealed sources?

TIA

Syd H. Levine
AnaLog Services, Inc.
Phone:  (270) 276-5671
Telefax:  (270) 276-5588
E-mail:  analog at logwell.com
Web URL:  www.logwell.com
 