[ RadSafe ] Removal of Cs-137 source from an old irradiator

Don Jordan donjordan at ramservicesinc.com
Tue Aug 16 08:37:28 CDT 2011


J.L. Shepherd may be interested in acquiring your source for re-use.  

-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu
[mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of Wasiolek, Maryla
Sent: Monday, August 15, 2011 5:57 PM
To: The International Radiation Protection (Health Physics) Mailing List
Subject: Re: [ RadSafe ] Removal of Cs-137 source from an old irradiator

Gentlemen, 

Thank you very much for the tips.  At some point we did contact OSRP, but
from what I understand, the removal of our source was not quite consistent
with their mission. The irradiator is rather large, about 6 feet tall, which
is why we thought we would try to remove the source for disposal, e.g., from
behind the shield wall using manipulators.  That is why I was looking for
the information on how the irradiator was constructed inside. 

Thanks again,

Maryla Wasiolek
Gamma Irradiation Facility
Sandia National Laboratories
Albuquerque, NM
505-844-3507    

-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu
[mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of ROY HERREN
Sent: Monday, August 15, 2011 3:43 PM
To: The International Radiation Protection (Health Physics) Mailing List
Subject: Re: [ RadSafe ] Removal of Cs-137 source from an old irradiator

The very best deal to be had for disposal of these types of items can be
found 
at Off-Site Source Recovery Project, OSRP, http://osrp.lanl.gov/.  The cost
to 
your facility will be minimal, that is if there is any cost at all.

 Roy Herren 




________________________________
From: "DrDonRhodes at cs.com" <DrDonRhodes at cs.com>
To: radsafe at health.phys.iit.edu
Sent: Mon, August 15, 2011 2:35:30 PM
Subject: Re: [ RadSafe ] Removal of Cs-137 source from an old irradiator

Hi,
      I had a similar problem 25 years ago involving 200 curies of Co-60 
in an experimental device which I designed and built.  I had a complete set 
of drawings, but I did not try to remove the sources.
      I got a type B shipping container from Chem Nuclear Systems, loaded 
the device, mixed and poured in concrete and shipped for disposal.
      This is expensive and does not help you much.
Good luck,
Ddon Rhodes
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the 
RadSafe rules. These can be found at: 
http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:

http://health.phys.iit.edu
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at:
http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://health.phys.iit.edu


_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the
RadSafe rules. These can be found at:
http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://health.phys.iit.edu