Radsafe:
 
      I know this is overkill or too expensive or  time consuming for some 
people/facilities, but one could readily set up a  rectangular radiation 
source using MCNP (Monte Carlo Neutral Particle Program)  and do a Monte Carlo 
Run (or a few) and solve the problem.  Do some of the  simpler computer 
radiation codes model a rectangular source????
 
     Regards,   Joe Preisig
 
 
 
 
In a message dated 7/12/2013 2:36:29 P.M. Eastern Daylight Time,  
daniel.s.simpson at nasa.gov writes:

George:



I don't see a WORD file  attached.


Daniel S. Simpson
Deputy Chief, Code 350 Occupational  Safety & Health Division
National Aeronautics and Space  Administration
Goddard Space Flight Center
Greenbelt, MD   20771
(301) 286-2281
Fax: (301) 286-1745



-----Original  Message-----
From: radsafe-bounces at health.phys.iit.edu  
[mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of George  Chabot
Sent: Friday, July 12, 2013 2:22 PM
To: 'The International  Radiation Protection (Health Physics) MailingList'
Subject: Re: [ RadSafe ]  formula and its derivation for rectangular 
extended radioactive sources  exposure rate



Regarding the rectangular source, attached is a  Word document showing the 
equation development. It is not possible to obtain a  complete algebraic 
solution to the required integration, but the resulting  equation is easily 
solved using numerical integration.



George  Chabot



-----Original Message-----

From:  
radsafe-bounces at health.phys.iit.edu<mailto:radsafe-bounces at health.phys.iit.edu>

[mailto:radsafe-bounces at health.phys.iit.edu]  On Behalf Of Danak, Subhash M 
CTR DOD CAPMED FBCH

Sent: Thursday, July  11, 2013 10:28 AM

To:  radsafe at health.phys.iit.edu<mailto:radsafe at health.phys.iit.edu>

Subject:  [ RadSafe ] formula and its derivation for rectangular extended 
radioactive  sources exposure rate



I like to review formula for rectangular  radioactive sources exposure rate.

Please provide one.

I thank  you.



Subhash

_______________________________________________

You  are currently subscribed to the RadSafe mailing list



Before  posting a message to RadSafe be sure to have read and understood 
the RadSafe  rules. These can be found  at:

http://health.phys.iit.edu/radsaferules.html



For  information on how to subscribe or unsubscribe and other settings  
visit:

http://health.phys.iit.edu
_______________________________________________
You  are currently subscribed to the RadSafe mailing list

Before posting a  message to RadSafe be sure to have read and understood 
the RadSafe rules.  These can be found at: 
http://health.phys.iit.edu/radsaferules.html

For  information on how to subscribe or unsubscribe and other settings 
visit:  http://health.phys.iit.edu