[ RadSafe ] Fwd: [New post] Tepco under-reported Fukushima release of plutonium - by 200 times!

KARAM, PHILIP PHILIP.KARAM at nypd.org
Tue Aug 12 13:25:51 CDT 2014


My reading of the Pu nuclides reported is that there were no shorter-lived (e.g. Pu-241) nuclides found.  This suggests that any Pu found was legacy from nuclear weapons testing and the Pu-238 RTG that burned up on re-entry in the 1960s.

Andy


-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu [mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of Jaro Franta
Sent: Friday, August 08, 2014 9:49 AM
To: 'The International Radiation Protection (Health Physics) Mailing List'
Subject: Re: [ RadSafe ] Fwd: [New post] Tepco under-reported Fukushima release of plutonium - by 200 times!

Roger,

There is in fact no need for any "results of the application of the fast-running US-NRC direct code RASCAL 4.2 to the estimation of the Fukushima Source Term."

The levels of plutonium have been measured on the ground - as documented in UNSCEAR Report 13-85418, 2013, Annex A, Table 2.

You can view the relevant text at the following link.  Note especially the parts underscored in red - both above and below Table 2.

https://db.tt/zxpyXzUk

The report itself can be found here:
http://www.unscear.org/docs/reports/2013/13-85418_Report_2013_Annex_A.pdf

PS. Why don't you come join the discussion at Nukes ?
https://www.facebook.com/groups/nukesgroup/

Cheers,

 Jaro
^^^^^^^^^^^^^^^^^^^^^^^^^




-----Original Message-----
From: radsafe-bounces at health.phys.iit.edu
[mailto:radsafe-bounces at health.phys.iit.edu] On Behalf Of Roger Helbig
Sent: August-08-14 6:37 AM
To: RADSAFE
Subject: [ RadSafe ] Fwd: [New post] Tepco under-reported Fukushima release of plutonium - by 200 times!

Is there any fact in this assertion?  Since Plutonium does not boil off, how is it supposedly released from the crippled reactor?  The anti-nukes constantly focus on uranium and plutonium because those two elements trigger fear in large numbers of people and they are masters of the art of creating and manipulating fear.

Roger Helbig

---------- Forwarded message ----------
From: nuclear-news <comment-reply at wordpress.com>
Date: Fri, Aug 8, 2014 at 12:05 AM
Subject: [New post] Tepco under-reported Fukushima release of plutonium - by
200 times!
To: rwhelbig at gmail.com


Christina MacPherson posted: "New report estimates 278 trillion Bq of plutonium released from Fukushima reactors -- Over 200 times higher than amount reported by Tepco -- "Highly radiotoxic when incorporated into human body" as it decays http://enenews.com/new-report-estimates-278-trill"
Respond to this post by replying above this line

New post on nuclear-news

Tepco under-reported Fukushima release of plutonium - by 200 times!

by Christina MacPherson

New report estimates 278 trillion Bq of plutonium released from Fukushima reactors -- Over 200 times higher than amount reported by Tepco -- "Highly radiotoxic when incorporated into human body" as it decays http://enenews.com/new-report-estimates-278-trillion-bq-of-plutonium-release
d-from-fukushima-reactors-over-200-times-higher-than-amount-reported-by-tepc
o?utm_source=feedburner&utm_medium=email&utm_campaign=Feed%3A+ENENews+%28Ene
rgy+News%29

Evaluation of the Fukushima Accident Source Term through the fast running code RASCAL 4.2(pdf),ENEA Bologna Research Centre, May 23,
2014: This Report presents the results of the application of the fast-running US-NRC direct code RASCAL 4.2 to the estimation of the Fukushima Source Term. [...] it is plausible that the ventings that TEPCO announced during the accident as being conducted from the wetwell were, as a matter of fact and because of the degraded conditions of the plants, conducted actually from the drywell. [...] wetwell properties imply releases which can be several oder of magnitudes lower than those from the drywell [...] it can clearly be seen that the most probable path is the combination of Drywell+Direct option [...] the true venting path, i.e. from Drywell instead of from Wetwell, is an extremely important issue. [...] in several instances when TEPCO tried to operate venting, in order to release pressure outside the building through the stack, it proved impossible [...] there are many indications that probably the radioactive material escaped from the drywell; this may have occurred without TEPCO's immediate knowledge and because of several factors; for example: structural damages to the pipings connecting drywell to torus room (vent piping bellows), due either to the earthquake, and/or to the too violent pressure and temperature increase in the D/W; leakages through the top head manhole, the top head flange, the piping penetrations, the electrical wiring penetrations, the personal airlocks, the S/C manholes, the machine hatches, etc. [...] The value of 1%/h was chosen by ENEA because of the possible highly damaged conditions of the Fukushima NPPs due to the BDB [Beyond Design Basis] earthquake.

> Table 7. Cumulative Source Term (Bq) TEPCO MELCOR

Pu-241 Total = 1.2E+12 (1,200,000,000,000 Bq)

> Table 7. Cumulative Source Term (Bq) ENEA RASCAL 4.2

Pu-241 Unit 1 = 6.52E+13 (65,200,000,000,000 Bq)
Pu-241 Unit 2 = 1.86E+14 (186,000,000,000,000 Bq)
Pu-241 Unit 3 = 2.67E+13 (26,700,000,000,000 Bq)
Pu-241 Total = 2.78E+14 (278,000,000,000,000 Bq)

Environmental Science & Technology (American Chemical Society), July 11,
2014: [S]tandard alpha spectrometry techniques [...] are not able [...] to measure 241Pu.

Boreal Environment Research (pdf), Feb. 28, 2014: The 241Pu isotope was introduced into the environment from [...] accidents that released nuclear reactor fuel, such as [...] the 2011 Fukushima catastrophe. As compared with other Pu isotopes in the environment that are alpha-emitting and long-lived, 241Pu is a short-lived isotope with a half-life of 14.35 years [...] 241Pu decays to the alpha emitter 241Am, that has a much longer half-life (432.2
years) and is highly radiotoxic when it is incorporated into either the human or animal body. [...] The 241Pu isotope has been studied less extensively than the α-emitting Pu isotopes for several reasons. Activity concentration of 241Pu cannot be determined from the same alpha spectrum as the Pu isotopes 238, 239, and 240, and extra effort is needed in order to analyze 241Pu concentration of a sample. Actually, 241Pu emits alpha particles, but they have so low probability (0.002%) that 241Pu cannot be measured directly by α-spectrometry [...]

See also: Japan TV: Radiation release during 'venting' was up to 500 times larger than thought for Fukushima reactor -- Surprising surge in radioactivity before explosions (VIDEO)

Christina MacPherson | August 8, 2014 at 7:05 am | Categories:
Fukushima 2014 | URL: http://wp.me/phgse-hQz

Comment    See all comments

Unsubscribe to no longer receive posts from nuclear-news.
Change your email settings at Manage Subscriptions.

Trouble clicking? Copy and paste this URL into your browser:
http://nuclear-news.net/2014/08/08/tepco-under-reported-fukushima-release-of
-plutonium-by-200-times/

Thanks for flying with WordPress.com
_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at:
http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit:
http://health.phys.iit.edu

_______________________________________________
You are currently subscribed to the RadSafe mailing list

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu