[ RadSafe ] Analog Eberline monitor background responses
Joe Shonka
jjshonka at shonka.com
Tue Feb 20 20:32:37 CST 2018
Mehran
In the late 1980s, I was the principal scientist on a project to calibrate, traceable to NIST, the post accident monitors (NUREG-0737) for the IPC Clinton Plant. Sargent & Lundy was the A/E for that plant. We conducted many tests on that system, and submitted a detailed final report. If you can’t find the report in S&L’s library, I think the USNRC would have a copy in the Clinton licensing docket in DC. I don’t think I still have a copy of the final report, but I will look in my old files just in case.
Good Luck
Joe Shonka
Joseph J. Shonka, Ph.D.
Shonka Research Associates, Inc.
119 Ridgemore Circle
Toccoa, GA 30577
770-509-7606
Sent from Mail for Windows 10
From: MEHRAN.A.MOHAMMADIAN at Sargentlundy.com
Sent: Tuesday, February 20, 2018 6:33 PM
To: radsafe at health.phys.iit.edu
Subject: [ RadSafe ] Analog Eberline monitor background responses
Hello, RadSafers! Long time listener / watcher but never poster here
looking for some help. I'm working on a project where there is an
identified need to quantify the external ambient gamma background response
of some analog Eberline particulate, iodine, and noble gas radiation
monitors (early 1980s vintage). I can't seem to find any documentation
listing the background response for the specific models installed in the
field in units of cpm / mR/hr (or similar).
Does anyone have information that can be shared with me regarding the
background response of any of the following configurations:
Particulate Monitor:
Vendor: Eberline
Detector: RDA-3A (Beta Scintillator)
Sample Chamber: SA-1 (Moving Filter Paper)
Interface Box: IB-2 (Operating in Gross Counting Mode)
Analog Display Module: EC2-7 (Capable of Fixed or Variable Background
Subtract)
Noble Gas Monitor:
Vendor: Eberline
Detector: RDA-3A (Beta Scintillator)
Sample Chamber: SA-3
Interface Box: IB-2 (Operating in Gross Counting Mode)
Analog Display Module: EC2-7 (Capable of Fixed or Variable Background
Subtract)
Iodine Monitor:
Vendor: Eberline
Detector: RDA-2A (Gamma Scintillator)
Sample Chamber: SA-2 (Fixed Cartridge)
Interface Box: IB-2 (2 SCA Cards, Automatic Gain Stabilized Mode)
Analog Display Module: EC2-7 (Capable of Fixed or Variable Background
Subtract)
I sincerely apologize if I sent this message before. The previous attempt
didn't appear to go through nor does it show up on the RadSafe Archives
for February 2018.
Thank you in advance!
--
Mehran Mohammadian, P.E.
Senior Associate (Licensed in IL)
Nuclear Power Technologies
Sargent & Lundy
office: 1-608-291-0447 | mobile: 1-920-312-0470
email: mmohammadian at sargentlundy.com
_______________________________________________
You are currently subscribed to the RadSafe mailing list
Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://health.phys.iit.edu/radsaferules.html
For information on how to subscribe or unsubscribe and other settings visit: http://health.phys.iit.edu
More information about the RadSafe
mailing list