[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Alpha contamination survey meters
Jack,
We have had good luck using the Eberline E-600 with the 380 A probe.
"Chadwick, Jack" wrote:
> I am interested in recommendations for a portable alpha contamination survey
> instrument and probe capable of accurately detecting 10 - 20 DPM on a smear
> or a direct frisk. The instrument must not have a response to beta or gamma
> radiations. The instrument will be used for unconditional release of
> equipment and personnel, so the response time needs to be tolerable for
> personnel frisking. If anyone has a positive experience with an instrument
> matching these characteristics I would appreciate your feedback.
>
> Jack Chadwick
> Humboldt Bay Power Plant
>
> ************************************************************************
> The RADSAFE Frequently Asked Questions list, archives and subscription
> information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html