[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: Has anyone replaced BWR condenser tubes?
Peach Bottom Atomic Power Station replaced their admiralty brass condenser
tubes with modules of titanium tubes in the early 1990s.
Albert W. Wolff
The Alpha Group & Assoc. L.L.C.
Building 771 Radiological Engineering
Rocky Flats Environmental Technology Site
303-966-5437
303-212-3729 (Pager)
-----Original Message-----
From: david.nestle@EXELONCORP.COM
[SMTP:david.nestle@EXELONCORP.COM]
Sent: Wednesday, March 14, 2001 12:42 PM
To: radsafe@list.vanderbilt.edu
Cc: peter.scardigno@EXELONCORP.COM
Subject: Has anyone replaced BWR condenser tubes?
Dresden Station is currently planning a power uprate project, which
will
include modifications to our condensers. The current plan is to
place
stakes in between the condenser tubes to provide additional bracing.
As an alternative, an engineer at the station is looking at the
possibility
of a full-scale replacement of the condenser tubes (that's 60,000
tubes per
condenser). He has asked that I pose a question to the listserve in
the
hopes that someone out there may have experience with a similar
evolution
with a BWR.
Any comments/suggestions should be forwarded to Pete Scardigno at
(815)
942-2920, ext. 2450 OR via email at peter.scardigno@exeloncorp.com.
Thanks.
______________________________________________________________
David R. Nestle, Health Physicist
Exelon Nuclear, Dresden Generating Station
T 815.942.2920 x3468
F 815.942.2920 x2563
www.exeloncorp.com
****************************************************************************
*****
This E-mail and any of its attachments may contain Exelon Corp.
proprietary
information, which is privileged, confidential, or subject to
copyright
belonging to the Exelon Corp. family of Companies. This E-mail is
intended
solely for the use of the individual or entity to which it is
addressed. If
you are not the intended recipient of this E-mail, you are hereby
notified
that any dissemination, distribution, copying, or action taken in
relation
to the contents of and attachments to this E-mail is strictly
prohibited
and may be unlawful. If you have received this E-mail in error,
please
notify the sender immediately and permanently delete the original
and
any copy of this E-mail and any printout. Thank You.
****************************************************************************
*****
************************************************************************
You are currently subscribed to the Radsafe mailing list. To
unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text
"unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject
line.
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
------------------------------