[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Abnormal Event ALARA Optimization
Does anyone have any references/opinions as to ALARA optimization for abnormal
events?
In general, optimization says that an the cost of an ALARA activity/dose
saving component is justified if that cost is less than the dose averted times
a $/person-rem value.
Is not the dose averted a function of the probability of the occurrence of the
problem that causes the dose? If a particular abnormal event has a dose
consequence of 10 rem but the probability of occurrence is only 1/20 years,
what value do you use for the dose averted calculation? 10 rem or 10 rem /20
years or 0.5 rem?
Any thoughts/references???
Tom Goff
WIPP ALARA Coordinator
WIPP Radiological Engineering
(505) 234-8861
(fax) 234-6027
e-mail GoffT@WIPP.Carlsbad.NM.US
page (505) 234-8850 (pager 479)
P.O. Box 2078
Carlsbad, NM 88221
Radiological Engineering: Anticipating Radiological Problems
Developing Techniques to Deal with Them
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.