[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: neutron shielding
One more neutron shielding option. Rad Shield makes water shielding
systems. They are portable, light weight, and can be drained and refilled.
The company is in Harrisville, WV. Their phone number is 304-643-4347 and
they do not have a web address.
S. Ziegler
Nuclear Technical Supervisor-RP
PSEG Nuclear LLC
Susanne.Ziegler@pseg.com
-----Original Message-----
From: Ayers, Rex G [mailto:Rex.Ayers@TycoHealthcare.com]
Sent: Thursday, June 27, 2002 6:58 AM
To: radsafe@list.vanderbilt.edu
Subject: RE: neutron shielding
I have some scatter coming out from under some shield doors of our
cyclotrons. The angle is such that the steel box would work well and give me
a greater cross-section of paraffin.
Thanks for the suggestions.
Rex Ayers, CHP
-----Original Message-----
From: JPreisig@AOL.COM [mailto:JPreisig@AOL.COM]
Sent: Wednesday, June 26, 2002 7:37 PM
To: radsafe@list.vanderbilt.edu
Subject: Re: neutron shielding
Hi Radsafers:
This is from jpreisig@aol.com .
Interesting stuff: paraffin encased in steel. Depending on the
neutron
energy, you might want to re-think your plans. Below 20 MeV, you might get
away
with what you are trying to do. Above 20 MeV, neutrons can go through
steel quite easily (there is a hole in the steel cross-section for
neutrons).
You
need to find out in what energy range this hole exists. You might shield
well
with the paraffin and still have the neutrons stream in along the steel
edges. Bummer.
At particle accelerators (intermediate energy and I think, high energy)
(proton machines) one has inner walls of iron/steel, and materials like
that.
Outside of the steel/iron, one has concrete without much (or any???)
steel/iron
reinforcing. The concrete stops the neutrons, not any steel/iron inside of
it. The internal wall steel/iron stops charged particles (i.e. protons).
Different
shielding situations are shielded differently than this.
Good Luck with your work.
Joe Preisig, Ph.D.
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
You can view the Radsafe archives at http://www.vanderbilt.edu/radsafe/
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
You can view the Radsafe archives at http://www.vanderbilt.edu/radsafe/
************************************************************************
You are currently subscribed to the Radsafe mailing list. To unsubscribe,
send an e-mail to Majordomo@list.vanderbilt.edu Put the text "unsubscribe
radsafe" (no quote marks) in the body of the e-mail, with no subject line.
You can view the Radsafe archives at http://www.vanderbilt.edu/radsafe/