Re: Badge Readings Part 2
Factors to investigate (purely a technical assessment):
1. This is an angular irradiation. Therefore, what angular Ck factors
are incorporated in the dose algorithm, is extremely important. ANSI
N13.11-2001 blind tests Cat II for up to +/- 60 degrees, in both the
H and V orientation. How a TLD responds, or other technology, should
be looked at.
2. Static or Dynamic exposure is not an issue with film, in that you
can see the patterns, and, can determine whether there is a single or
multiple static exposure.
3. What did the dose algorithm determine the potential energy of the
exposure come from. Algorithm uncertainty can be considerable,
depending on the sophistication of the algorithm development.
Any provider of dosimetry should be asked how the above is handled,
they should provide the program details, and have the documentation
put in writing.
------------------------------------