[ RadSafe ] Germany to compensate 500 ex-soldiers who developed cancer after radiation exposure

Robert Atkinson robert.atkinson at genetix.com
Fri Jul 1 13:06:17 CEST 2005


Hi,
It's not clear from the report if the cause was ionising or non-ionising radiation. DU is not used in radar sets as far as I know, but other isotopes typically are. These include Kr85, Ni63, Cs137 and Ra226 in voltage regulator and T/R tubes (valves) to maintain a small level of ionisation, H3 and Ra226 for control illumination and Uranium glass in glass to metal seals in high power tubes.
They can also have a lot of toxins including lead, beryllium (metal and oxide) cadmium and PCB's (not the circuit board!).

Regards,
Robert Atkinson 
MRAeS G8RPI.


-----Original Message-----
From: radsafe-bounces at radlab.nl [mailto:radsafe-bounces at radlab.nl] On Behalf Of Franta, Jaroslav
Sent: 30 June 2005 18:47
To: radsafe
Subject: RE: [ RadSafe ] Germany to compensate 500 ex-soldiers who developed cancer after radiation exposure

German soldiers and their families have long sought damages for 
illnesses such as leukemia and testicular cancer that they believe is 
the result of poor protection against radiation from radar equipment.
<SNIP>


Soooo.... was this radar equipment made of DU, or what ?

Jaro 
^^^^^^^^^^^^^^^^^^^
CONFIDENTIAL AND PRIVILEGED INFORMATION NOTICE

This e-mail, and any attachments, may contain information that
is confidential, subject to copyright, or exempt from disclosure.
Any unauthorized review, disclosure, retransmission, 
dissemination or other use of or reliance on this information 
may be unlawful and is strictly prohibited.  

AVIS D'INFORMATION CONFIDENTIELLE ET PRIVILÉGIÉE

Le présent courriel, et toute pièce jointe, peut contenir de 
l'information qui est confidentielle, régie par les droits 
d'auteur, ou interdite de divulgation. Tout examen, 
divulgation, retransmission, diffusion ou autres utilisations 
non autorisées de l'information ou dépendance non autorisée 
envers celle-ci peut être illégale et est strictement interdite.
_______________________________________________
You are currently subscribed to the radsafe mailing list radsafe at radlab.nl

Before posting a message to RadSafe be sure to have read and understood the RadSafe rules. These can be found at: http://radlab.nl/radsafe/radsaferules.html

For information on how to subscribe or unsubscribe and other settings visit: http://radlab.nl/radsafe/
 
Any opinions expressed in this email are those of the individual and not necessarily Genetix Ltd (Genetix) or any company associated with it. This email and any files transmitted with it are confidential and solely for the use of the intended recipient. If you are not the intended recipient or the person responsible for delivering to the intended recipient, be advised that you have received this email in error and that any use is strictly prohibited. If you have received this email in error please notify Genetix by telephone on +44 (0)1425 624600. 
 

The unauthorised use, disclosure, copying or alteration of this message is strictly forbidden. This mail and any attachments have been scanned for viruses prior to leaving the Genetix network. Genetix will not be liable for direct, special, indirect or consequential damages as a result of any virus being passed on, or arising from alteration of the contents of this message by a third party. 
 



More information about the radsafe mailing list