Re: Radioiodine Sampling



Erick:
|TAB|Try the SKC iodine-dedicated treated charcoal tubes
for low-flow applications.
They're the standard 6-7 cm. glass break-off type;
we use these for breathing zone and area monitoring.
They are catalog #226-67.
 
SKC, Inc.
334 Valley View Road
rr1 Box 334
Eighty Four, PA 15330-9614
(800) 752-8472
 
 
************************************************
Tom Schumacher
RSO- VA Medical Center
Indianapolis, IN