[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Tritium Control Data
Mr. Dunn,
>Having just received in 10Ci tritium gas in a glass ampule,
- similar, no doubt, to other glass ampules in which other amounts of
tritium gas may have been, or may yet be, delivered to all our institutions -
>we were able to easily see counts on a GM (pancake probe)
>[and obviously even more with a NaI(Tl)].
Then by all means, please share those meter responses with the rest of us.
GM: How many cpm near surface of ampule? How many cpm (same instrument) in
1 mrem/hr Cs-137 gamma source field?
NaI: How many cpm near surface of ampule? How many cpm (same instrument) in
1 mrem/hr I-125 photon source field?
Those numbers might be helpful to us, conceivably. Thanks.
Albert Lee Vest The Ohio State University
Health Physicist B-042 Graves Hall
(614)292-0122 333 West 10th Avenue
"Action brings good fortune" - Syd Barrett
"Rock n roll" - John Goodman Columbus OH 43210
My employer did not review or approve this message.