[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Tandem accel question
Keep in mind the currents being considered: 1 and 30 micro-amps.
These are very small currents and, although in the low MeV,
I would expect no significant rad levels. At IBM Watson Lab
we installed a 1 MeV Pellatron and have the end stations and
control console in the same room. The vendor did wrap some
lead around the tank and I had area monitors up for over a
year with nothing but background. Think of it as a high-end
ion implanter. I did require area gamma and neutron monitors
be installed, interlocked to the accel, and set to some
low trip point like 1 - 2 mrem/hr.
We did build a shielded room for some neutron work. The
researchers could accel He++ into a Be foil. This room
had the interlocked door. The tandem accel itself was
basically a non-rad generator so the main room only had a
special badge reader on it.
Hope this helps.
Jeff
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
Jeffrey Leavey certhp@vnet.ibm.com
X-ray Lithography Program IBM Corp.
914-892-4595 East Fishkill, NY 12533
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=