> Reply to: RE>Static Magnetic Field Guidelines
>
> More recent guidance can be found in International Commission on Non-Ionizing
> Radiation Protection. "Guidelines on Limits of Exposure to Static Magnetic
> Fields," Health Phys. 66, 100-106 (1994). ICNIRP specifies:
>
> o A 2000 gauss time-weighted average exposure criterion,
>
> o 30 gauss as where metallic implants and tools can become hazardous,
>
> o 10 gauss as where credit card stripes can be erased, and
>
> o 5 gauss as the pacemaker/electronic implant warning criterion.
>
> The 600 gauss limit was developed by Tom Tenforde, now with PNL, and I. I
> actually calculated the number. The background for the 600 gauss limit is
> found in G. C. Miller. "Exposure Guidelines for Magnetic Fields," J. American
> Industrial Hygiene Association, 48, 957-968 (1987).
>
> LLNL now uses the ICNIRP limit of 2000 gauss and I have written to the Chair
> of the Physical Agents TLV Committee advising them to adopt the 2000 gauss
> limit.
>
> If there are further questions, please contact me at:
>
> Internet: gordon.miller@quickmail.llnl.gov
>
> Lawrence Livermore National Laboratory, P. O. Box 808 (L-289), Livermore, CA
> 94551-0808
>
> Phone (510) 423-8036
> Fax (510) 423-1086
Is this 2000 Gauss or 2000 milli gauss?