> However, other regulations require maxium dosimetry periods of 1
> month for film and 3 months for TLDs.
Some states currently allow film dosimetry to be worn for a quarter,
and, there is a move within the power reactor world towards
semi-annual as well as annual TLD processing. There are a few that
are currently processing semi-annually. For optimum results with the
least external factors affecting the dosimeter response, it is my
recommendation that film be processed monthly and a TLD not exceed a
quarterly processing. This is not to say that good dosimetry as well
as good results can't be obtained beyond these time periods. A result
is only as good as the program implemented, the algorithm and all
factors contained within it, and, most importantly, the Quality
Assurance Program implemented.
------------------