Re: : Leak Testing Sealed Sources
HALEEM MAHMOUD SAID wrote:
>
> I am having troubles convincing people here regarding the leak testing of
> sealed sources. AT our university we have smalled sealed sources of
> alpha and gamma. The activities range from few microcuries down to
> submicrocuries. Most of the sources are rarely used. I need your
> cllective efforts in helping me in pointing out what are the trigger
> levels for leak testing of sealed radioactive sources.
>
> YOUR input is much appreciated. Thanks
>
> Mahmoud Haleem
> KFUPM
> P.O.BOX 1061
> Dhahran, 31261
> Saudi Arabia
> mshaleem@dpc.kfupm.edu.sa
In the State of Colorado if your sealed sources have a total activity
less than 100 microcuries for Beta or photon-emitting or 10 microcuries
for Alpha-emitting, they are considered exempt from leak testing
requirements.
--
<><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><>
Steven L. McQueary, NRRPT mcqueary@lamar.colostate.edu
Colorado State University Phone: (970) 491-3928
Radiation Control Office Fax: (970) 491-4804
<><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><><>