[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: High Contamination
Several people have asked about the isotopic constituents of our
contamination so I am listing the results from a smear taken at the
point of highest contamination. Again, the challenge I have is to put
together a decon technique which will lower the levels of contamination
in the drywell in order to facilitate required work during the Oct.
outage without spreading it throughout and making a bad situation worse.
Thanks to all who have already replied.
Activities are in uCi/cm2
Cr-51 2E-4 Ag-110m 7E-5
Mn-54 3E-5 I-131 3E-4
Co-58 3E-5 I-133 1E-5
Co-60 5E-5 Cs-134 4E-4
Zn-65 1E-4 Cs-136 3E-5
Sr-92 3E-5 Cs-137 3E-4
Tc-99m 8E-6
Mike Mitchell
=======================================================
Michael. T. Mitchell
Health Physicist
Tennessee Valley Authority
Browns Ferry Nuclear Plant
Phone: (205) 729-2401
Fax: (205) 729-3157
mailto:mtmitchell@tva.gov