[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Neutron dose factor, comments
Thank you, Les, for your detailed response on neutron dose calculations.
Are you familiar with the calculations of Leuthold, which drive ICRP60?
(see ICRP page 85.) In particular, what causes Q to be the same, near 100
keV, as the Q for alpha particles? Does this mean the dose from (n,g) is
negligible near 100 keV?
"Shlala gashle" (Zulu greeting, meaning "Stay safe")
mike (mcnaught@LANL.GOV)
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html