VA Power, Surry and North Anna Power Stations employ the Eberline PCM-1B and
PCM-1C, which use gas proportional detectors, at the RCA exits and have been
satisfied with their performance.  These are source checked using a NIST
traceable 5,000 dpm Tc-99 source one inch away from each detector and on contact
with the foot detectors.  During outages we open the secondary security and
employ the Eberline PM-6A monitors, which also use gas flow proportional
detectors.

Carl Tarantino
Senior Staff Health Physicist
VA Power Corporate, Nuclear Licensing & Ops Support
tarantino@vapower.com





"Poston, Jay (John) (PEA)" <jposton@guidant.com> on 05/20/99 09:41:18 AM

Please respond to radsafe@romulus.ehs.uiuc.edu

To:   Multiple recipients of list <radsafe@romulus.ehs.uiuc.edu>
cc:    (bcc: Tarantino/NUC/VANCPOWER)
Subject:  Personnel Contamination Monitor





I am looking to purchase a PCM for beta contamination monitoring.  What is
out there?  What is your favorite?  What is your least favorite?  If you're
a vendor, please contact me directly.

Thank you,
J. W. Poston, Jr., Ph.D., C.H.P.
Guidant Corporation
Vascular Intervention - Houston
1122 North Main Street
Pearland, Texas  77581

Work:     713-218-9312
Fax: 713-218-9332
Cell:     713-303-4017
Pager:    888-371-7307
E-mail:   Jposton@guidant.com
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html






************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html