RE: Real time monitoring of atmospheric tritium
The lowest detection limit I have seen quoted is 17 Bq/m3 for a 24 hr
measurement with a Berthold gas flow proportional counter (3 L). However,
it is debatable if 24 hours is considered real time. I assume that this
detection limit will be significantly more in the presence of any background
interferences.
M.J. Wood
Michael J. Wood
Radiation Biology and Health Physics Branch
Chalk River Laboratories
Chalk River ,Ontario, Canada K0J 1P0
E-mail: woodm@aecl.ca
Phone: 613-584-8811 (4750)
FAX: 613-584-1713
> ----------
> From: Jean-Michel Mure[SMTP:jm.mure@andra.fr]
> Reply To: radsafe@romulus.ehs.uiuc.edu
> Sent: Tuesday, July 27, 1999 9:31 AM
> To: Multiple recipients of list
> Subject: Real time monitoring of atmospheric tritium
>
> Hello,
>
>
> I am looking for an equipment that would allow a real time monitoring of
> atmospheric tritium. The only one I have found so far has detection limit
> of 30 000 Bq/m3.
>
>
> Is anybody aware of a more sensitive monitoring device ? If yes, can you
> please give the detection limit and the adress of the supplier ?
>
>
> Best regards,
>
>
>
>
>
>
>
>
>
>
>
> ***************************************************
>
> Jean-Michel MURE
>
> French National Radwaste Management Agency
>
> <bigger>(ANDRA)
>
> </bigger>Safety Division
>
> Security and Radiological Protection Department
>
> Parc de la Croix Blanche
>
> 1-7, rue Jean Monnet
>
> 92290 CHATENAY MALABRY Cedex
>
> FRANCE
>
> ****************************************************
>
> Tel : 33 1 46 11 83 74
>
> Fax : 33 1 46 11 80 13
>
> ****************************************************
>
> Email : jm.mure@andra.fr
>
> ****************************************************
> ************************************************************************
> The RADSAFE Frequently Asked Questions list, archives and subscription
> information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html
>
************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html