[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Information ...



> characterize our irradiation facilities?

We use Keithley Model 616 digital electrometer and an Exradin Model 
A-3 and A-5 Shonka-Wycoff ionization chambers. In concert with this, 
we also use Bicron-NE TLDs afterwards to validate the data collected.

The above electrometer and chamber data ia used to map the 
irradiation facility, and is plugged into a spread-sheet directly 
from the measurements. Dose rates are procedurally adjusted in 
between the verification and the establishment of new calibration 
data.


------------------------------------------------------------------------
Sandy Perle					Tel:(714) 545-0100 / (800) 548-5100   				    	
Director, Technical				Extension 2306 				     	
ICN Worldwide Dosimetry Division		Fax:(714) 668-3149 	                   		    
ICN Biomedicals, Inc.				E-Mail: sandyfl@earthlink.net 				                           
ICN Plaza, 3300 Hyland Avenue  		E-Mail: sperle@icnpharm.com          	          
Costa Mesa, CA 92626                                      

Personal Website:  http://www.geocities.com/capecanaveral/1205
ICN Worldwide Dosimetry Website: http://www.dosimetry.com

************************************************************************
The RADSAFE Frequently Asked Questions list, archives and subscription
information can be accessed at http://www.ehs.uiuc.edu/~rad/radsafe.html