Hullo All
 
Can anyone suggest a suitable method of doing out a broad brush test to separate crushed ore  samples into two groups, those that  have less definitely less than 10 Bq/g and those which may have more than 10 Bq/g. The assessment confirming that a sample had a gross activity of less than 10 Bq/g would have to be generally acceptable. to purchasers of the ore and to local regulatory authorities.  The following equipment is available.
 
40 mm diameter Zinc Sulphide alpha probe, 40 mm diameter pancake GM detector, 40 mm diameter 1 mm thick Sodium Iodide low energy gamma detector, scalars for sample times of 1 second to 4 hours.
 
Are the following assumptions valid?
 
1 gram of ore dust sample spread over a 38 mm diameter dish. gives a maximum absorber of 89 mg/cm squared. Transmission of beta energy more than 100 keV is more than 50%.
 
 
 
 
All comments welcome
 
 
 
  
 
 
Yours Faithfully,
Mike Malaxos
For Radiation Safety Services
Mike@radiationsafety.com.au
P 61 8 475 0099
P. 61 8 2551214 a/h
Licence  No LS 198 89  5866