John... here is my attempt...
It seems that Am-241 has approximately a 60 keV x-ray (36%) ... that
is between the NVLAP M100 and M150 Categories.
M100 average energy Kev .. Ck,d = 1.65 Ck,s = 1.62
M150 average energy keV .. Ck,d = 1.92 Ck,s = 1.78
Hope this helps a little.
Sandy Perle
Supervisor Health Physics
sandy_perle@email.fpl.com
______________________________ Reply Separator _________________________________
Subject: NVLAP/DOELAP
Author: radsafe@romulus.ehs.uiuc.edu at Internet-Mail
Date: 8/18/95 11:23 AM
Thanks to those who responded to my query on rad waste.
A question for any dosimetry gurus out there. What is the Cx or Ck value for
Am-241 x-rays in the ANSI N13.11 world? I realize that Am-241 is not a NVLAP
source, but I am trying to convert some DOELAP style irradiations to the ANSI
values. I have the proper values for the standard beams, but the AM-241 is
lacking.