Re: S-35 Volatility
In regards to the notes on S-35 volatility, I ask the same question
we did when this first arose (mid-80's?):
Is this a problem?
ALI S-35 = 1 mCi
The typical vial of S-35 used is 1 mCi or less. Most individual
research labs use much less than 100 mCi/year. If one individual
opened all 100 mCi, 0.1% = 100 uCi = 10% ALI IFF they snorted the
entire volatile fraction. Is this really a reasonable scenario?
NOTE: It was still "strongly recommended" (e.g., I don't recall if we
allowed any exceptions) that ALL vials be initially opened in an
operating fume hood.
Wes
*********************************************************************
Wesley M. Dunn, C.H.P., Administrator 512-834-6688
Licensing Branch 512-834-6690 (fax)