[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Film Dosimeters - Multiple Badges for individuals who go to multiple locations- opinions please



Soliciting opinions -
We just had an FDA Mammo inspector ask that we have every radiologist, 
radiology technician and biomedical repair technician that we use become
separately badged at every one of our 22 different departmental locations 
within our health care system.  We have previously treated this as one 
Hospial System with but he says that the Landauer Multiple Employer Total 
Exposure Report (METER) system that shows when they moonlight is not 
enough.  By badging each location, you could show exactly where an exposure 
was received. (Despite our QC, calibration and area monitor systems.  
Intends to write us up as a Class III violation. What do you do on this?   
Comments please, so I can present other opinions to my Radiation Safety 
Committee.
Mark Steinbuchel, CHCM
Alternate Radiation Safety Officer
Huntsville Hospital System
markst@ONC.hhsys.org