Stuart, Take a look at Reg. Guide 8.32 "Criteria for Establishing a Tritium Bioassay Program" (Jul 1988). It's available in PDF or ZIP at http://www.radtrain.com/rg.shtml Regards, Ben ben.morgan@cplc.com >---------- >From: Stuart Prosser[SMTP:s.prosser@unsw.edu.au] >Sent: Wednesday, June 10, 1998 02:49 >To: Multiple recipients of list >Subject: monitoring for tritium > >Dear RADSAFERS, > >Can you please give me an indication of at what levels of activity of >tritium it would be prudent to recommend urinalysis. Our two major uses >are; common lab applications of tritium-labelled reagents eg H3-thymidine; >and larger activities of tritiated water used in large animal experiments. >Thanks, >Stuart Prosser >**************************************************************************** >***********Dr Stuart Prosser tel: (02) 9385 2912 >Radiation Safety Coordinator fax: (02) 9385 2365 >The University of New South Wales email: s.prosser@unsw.edu.au >**************************************************************************** >*********** >