[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

FW: DDE and the Interventional Cardiologist







 -----Original Message-----

From: 	Danny K. McClung [mailto:danny.mcclung@nist.gov]

Sent:	Wednesday, August 14, 2002 11:01 AM

To:	Radsafe-Owner (E-mail)

Subject:	DDE and the Interventional Cardiologist



>From experience with US Army dosimetry program:



The interventional cardiologist wears 3 dosimeters:  one on the dominant

hand (extremity), one behind the apron (whole body), one on the collar

outside the apron (head & neck badge). The head & neck badge measures dose

to the lens of the eye (which has a different annual limit). A formula is

then applied to calculate EDE to the whole body using numbers obtained from

the two badges.



Regards,



~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Danny K. McClung, RRPT

Reactor Health Physicist

NIST Center for Neutron Research

100 Bureau Drive, Stop 3543

Building 235, Room A135

Gaithersburg, MD 20899-3543



(301) 975-5812

 <danny.mcclung@nist.gov>

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

*The opinions expressed in this message are strictly my own.*



************************************************************************

You are currently subscribed to the Radsafe mailing list. To unsubscribe,

send an e-mail to Majordomo@list.vanderbilt.edu  Put the text "unsubscribe

radsafe" (no quote marks) in the body of the e-mail, with no subject line.