On this thread there have been several comments on the composition of the hood to
prevent plating out of the iodine so that the hood can be *decommissioned*. This is all
well and good but there is still the duct work, plenum, blower, and stack. For
*decommissioning* as specified in 10 CFR 30, the radioactive material plated out on
these surfaces must also be considered, correct? If you are talking about
*decontaminating* the hood surface for unrestricted use, then these considerations are
appropriate. Let's not confuse decontaminating a local work area with decommissioning a
facility.
--